 ====== Dissolving Tank ====== ====== Dissolving Tank ======
  
-Liquid Temperature in the tank: **95 – 98 <sup>o</sup>C** *Andritz\\ +Liquid Temperature in the tank: **95 – 98 <sup>o</sup>C** *[[misc:manufacturers:boiler_oem|Andritz]]\\ 
-Liquid Temperature in the tank: **194 – 207 <sup>o</sup>F** *Valmet\\+Liquid Temperature in the tank: **194 – 207 <sup>o</sup>F** *[[misc:manufacturers:boiler_oem|Valmet]]\\
  
 Too low temp = risk of pirssonite forming (crystallization)\\ Too low temp = risk of pirssonite forming (crystallization)\\
Line 11: Line 11:
 Dregs total: **1000 – 1500 mg/l**\\ Dregs total: **1000 – 1500 mg/l**\\
  
-Normal operating level: **50% +/- 15%** *Andritz\\ +Normal operating level: **50% +/- 15%** *[[misc:manufacturers:boiler_oem|Andritz]]\\ 
-Retention time: **>25 minutes** *B&W+Retention time: **>25 minutes** *[[misc:manufacturers:boiler_oem|B&W]]
  
  